Manufacturers ophthalmic microsurgical instruments, manufacturers disposable needles, manufacturers automobile components, Manufacturers bulk cannulae, manufacturers cannulaes, manufacturers ophthalmic microsurgical cannulae, Manufacturers disposable needles, manufacturers disposable syringes, manufacturers biopsy needles, re-usable surgical products, re usable surgical products, reusable surgical products, suture needles, bulk cannulaes, iso 9002 certified company, pricon, india, rajasthan, jodhpur

Home

Profile

Query Contact

Introduction

Current News

Sitemap

(02 Aug, 2010)
(01 Aug, 2010)
all news..

Irrigation & Aspirating :: ......................

J129 : I & A Cannula ( Simcoe Regular)
Aspiration through tubing 0.30 mm, Port, 23G
J-129-0.3 23/23G 0.30mm port
J129-0.4 23/22G 0.40 mm port
J-129 LH-Aspiration on Right for Left handers

J133 : I & A Cannula ( Simcoe Reverse)
Aspiration through hub 0.30 mm port, Irrigation through tubing.

J135 : I & A Cannula (Blasted) Simcode-Dahan
Same as J129 but both the cannula tips are sand blasted at bottom to fascilitate polishing posterior or anterior capsule 0.40mm
J137 Reverse Model 23G/22G

J145 : I/A Cannula U-shape left ( Grandon)


J147 : I & A Cannula (Daljeet)
Coaxial design ensures minimum trauma at entry and exit to the a/c also the design fascilitates to keep the capsule away from the aspirating port.

J1149 : J Shaped I & A Cannula ( Regular )
J shape fascilitates removalof cortex at 120 degree clock position
J1149 Regular
J1149-L : Left
J1149-R : Right
J1150 Reverse
J1150-L : Left
J1150-R : Right
0.30mm top port

J1151 : I & A Cannula (Modified) (Simcoe)
Aspiration through 23G tubing and irrigation through 0.50mm (22G) bottom port. Bottom irrigation keeps capsules away from the aspiration port
. J1152 Same as 1151 but Reverse Model

J1153 : I / A Cannula (Simcoe-Navia)
U - shaped extension curves downward for 12 O' clock cleanup 0.3 mm inside port.
23G/23G

J1154 : I & A Cannula (O' Gawa)
0.3 mm side port asp.Straight shaft with beveled tip.
J1154-16 : 16G
J1154-18 : 18G
J1154-20 : 20G.

J131 : I & A Cannula (Simcoe) with silicon Bulb
Specially designed hub eliminates use of adopter and directly fits in the silicon bulb. Inside taper 6% luer, can also be used with syringe. Regular.
J131 WB-3 0.30mm port
J131 WB-4 0.40mm port.
  Pages : - 1 2

Home | Profile | Query Contact | Introduction | Current News | Sitemap | Medical Division | Engineering Division